Arc-suppression coil In China's 3-35KV power supply system, most of them are ungrounded neutral systems. In the event of single-phase grounding, the power grid can still operate with faults, which greatly reduces operating costs and improves the reliability of the power supply system.
Overview

 

Arc-suppression coil in China's 3-35KV power supply system, most of them are ungrounded neutral systems. In the event of single-phase grounding, the power grid can still operate with faults, which greatly reduces operating costs and improves the reliability of the power supply system. However, this power supply method is prone to arc grounding overvoltage and phase to phase short circuit when the single-phase grounding current is high, causing great harm to the power supply equipment. The previous solution was to install an arc suppression coil at the neutral point to compensate for capacitor current and suppress the probability of arc light occurring at the fault point. It is obvious that the purpose of this method is to eliminate arc light, but due to the many characteristics of the arc suppression coil itself, it is difficult to effectively compensate for the capacitance current, especially the harm caused by the high-frequency component to the power supply equipment cannot be overcome. Intelligent arc suppression device, which uses a set of vacuum contactors that can be controlled in phases to ground the faulty phase when arc grounding occurs, achieving the goal of completely eliminating arc light.

 

Model number and its meaning

 

product-867-198

 

Use environmental conditions

 

Environmental temperature: Indoor type -15 ℃+60 ℃ Special can achieve -30 ℃ -+60 ℃

Altitude: ≤ 2000m, special circumstances can reach 4000m

Usage environment: There must be no explosive mixtures such as dust, gas, smoke, etc

 

Product features

 

Using PHILIPS company's 32-bit processor based on ARMTTDMI-S core, using multi-core technology for data collection and analysis judgment, with clear division of labor among units, greatly improving the collection rate and making judgments more accurate.

When a single-phase arc grounding occurs in the system, it can be quickly converted to metal grounding

When the system generates metal grounding or PT disconnection, the device will alarm in a timely manner

Cycle detection of PT open delta voltage, real-time data collection, and analysis and calculation of data through digital signal processing techniques such as digital measurement, filtering, and amplification. If a fault occurs, the current fault type is determined; If it is ferromagnetic resonance, immediately start the harmonic elimination circuit to eliminate ferromagnetic resonance at frequencies of 17Hz (1/3 division), 25Hz (1/2 division), 50Hz (power frequency), 150Hz (3rd harmonic), and above

Can choose between automatic or manual switching

This device has an accident memory function, which can record the time of 30 events and the action status of the device.

product-958-477

 

product-500-500
product-4000-3000

Hot Tags: 6kv/10kv/10.5kv Arc-suppression Coil, China 6kv/10kv/10.5kv Arc-suppression Coil manufacturers, suppliers, factory, customizable capacitor cabinet, advanced capacitor cabinet, power factor correction in telecommunication towers, capacitor cabinet switches, easy installation capacitor cabinet, active power factor correction