Overview
The application of NRSVG dynamic reactive power compensation and harmonic control device with IGBT as the core, is the most advanced dynamic reactive power compensation technology and the most mature voltage source converter technology, which makes the reactive power compensation device achieve a qualitative leap. Reactive power compensation realizes the transformation of nonfunctional quantities by high-frequency switching of high-power power electronic devices ,not the capacitors and inductors with large capacity anymore.
Product features
1. Modular design, easy installation, debugging and setting.
2. Fast dynamic response, response time < 5 ms.
3. On the premise of sufficient compensation capacity, output current harmonic (THD) ≤3%.
4. A variety of operation modes can greatly meet the needs of users, including constant device reactive power mode, constant check point reactive power mode and constant check point power factor mode, constant test point voltage mode, constant test point reactive power mode 2, the target value can be changed in real time.
Model and significance

Note: Capacity (Mvar) refers to the rated maximum adjustable capacity within the dynamic adjustment range from inductive reactive power to capacitive reactive power. For example, c2.0/10 indicates:
A device with a capacity of ±2Mvar and a capacity of 10kV. Reactive power can be advanced in the range of +2000kvar (sensibility) to -2000kvar (capacitive) Row continuous smoothing adjustment.

NRSVG series adopts fan forced cooling
1) Height of indoor device does not include height of fan (about 500mm).
2) Capacity (Mvar) Indicates the rated maximum adjustable capacity within the dynamic adjustment range from inductive reactive power to capacitive reactive power. For example, C10.0/10, table Is shown as a 10kV device with a capacity of ±10Mvar, that is, continuous smoothing of reactive power within the range of +10Mvar (perceptual) to -10mvar (capacitive) To adjust.
3) The above dimensions are for reference only, and the company reserves the right to upgrade and improve the product. The size of the product will not be changed without prior notice.
4) For 35kV series products, the three-phase can be divided into three rows before and after the nearby layout.
Main components and functions of NRSVG

Hot Tags: reactive power compensation capacitor, China reactive power compensation capacitor manufacturers, suppliers, factory, capacitor cabinet circuitry, single phase power factor corrector, active power factor correction, power factor correction for battery storage, waterproof capacitor cabinet, power factor correction for electric vehicles