Product sheet 01 · 10 kV reactive power compensation
TBBZ-10-1000/334kvar-AK/P6
A complete reactive power compensation installation, not a kit of parts: vacuum switching, dry-type reactors, capacitor banks and control in one lineup.
- 10 kV Rated voltage
- 1000 kvar Rated capacity
- 4 Cubicles
- 220 V Control voltage

02 / Switching & isolation
Vacuum switching, visible isolation
Every bank can be worked on once the break is verified

- Vacuum contactor JCZ5-12D/D630A 12 kV, 630 A contactor with AC/DC 220 V coil; switches each capacitor bank without arc restrike.
- Isolating & earthing switch Visible break plus verified earthing before the compartment is opened; mechanically interlocked with the door.
- Current transformer Supplies the measured current to the controller and protection relays for switching decisions.
03 / Capacitor bank
Capacitors with series reactors
Inrush limited, harmonic resonance avoided

- Capacitor units High-voltage shunt capacitor units, phase-marked and rack-mounted; the working heart of the bank.
- Series reactor Dry-type iron-core reactor in series with each bank; limits inrush and detunes the bank.
- Discharge coil Discharges the residual charge to a safe level before maintenance access; connected across each bank.
- Surge arrester Limits switching and lightning overvoltages at the bank terminals, protecting the capacitors.
04 / Busbar & cooling
Current path and heat path
Sized for the full lineup, not just this bank

- Main busbar The phase-marked copper busbar runs the full length of the lineup, ready for extra cubicles without rework.
- Cooling fan Roof-mounted axial fans move air through capacitor and reactor compartments to keep compartment temperature within limits.
- Post insulator Supports and insulates the busbar run; creepage selected for the 10 kV class.
05 / Interior layout
Three layers, one main circuit
Busbar on top, reactors in the middle, capacitors below

- Compartment split Busbar top, reactors middle, capacitors bottom; heat stays away from the capacitors.
- Front access Each component is visible and reachable from the front; no rear gangway required.
- Parallel extension Cubicles bolt together on one busbar run; capacity grows bay by bay.
06 / Secondary
Wired, numbered, documented
Site electricians can trace a circuit unaided

- Relays & MCBs Intermediate relays and miniature circuit breakers on a removable panel, sized per circuit.
- Terminal blocks Numbered ferrules on every core, spare terminals reserved for remote signalling.
- Wiring diagram Cabinet drawings are supplied in the door pocket, updated to match the wiring as built.
07 / Control
Power factor held at target
Working and measuring voltage: 220 V

- Controller Compares the measured power factor with the target value, then steps banks in and out.
- Sampling inputs Takes voltage and current from the instrument transformers; no extra sensors required.
- Relay outputs Drives each contactor coil; switching delay and lockout set on site.
08 / Safe access
Check before you open
Operation, isolation and earthing in one sequence

- Inspection window Verify contactor position and labels without opening a live compartment.
- Mechanical interlock Prevents the door from opening while the isolating switch is closed.
- Operating handle Racking and switching from the front, with position indicators at eye level.
09 / Specification
The numbers behind the lineup
| Model | TBBZ-10-1000/334kvar-AK/P6 |
|---|---|
| Rated voltage | 10 kV |
| Rated capacity | 1000 kvar, 3 x 334 kvar steps |
| Cubicles | 4, 1 control cubicle and 3 capacitor cubicles |
| Switching device | Vacuum contactor JCZ5-12D/D630A, AC/DC 220 V |
| Isolation | Isolating switch and earthing switch, mechanical interlock |
| Series reactor | Dry-type, iron-core, reactance ratio set by the harmonic study |
| Protection | Zinc-oxide arrester, discharge coil, current transformer |
| Control | Reactive power controller, 220 V working and measuring voltage |
| Cooling | Forced air, roof-mounted axial fans |
| Busbar | Phase-marked copper busbar, full length for parallel extension |
| Enclosure | Metal-enclosed, spray-coated, inspection window per compartment |
Tell us the load. We size the bank.
We send a single-line diagram, cubicle arrangement and a bank schedule sized to your load, usually within two working days.
Related equipment
- 6.3 kV 915 kvar high voltage capacitor bank
- 11 kV 120 kvar high voltage capacitor bank
- High voltage capacitor compensation cabinet
- Projects delivered by country
- Capacitor compensation cabinets series, 3 kV to 220 kV
Hot Tags: 10kv reactive power compensation, 1000 kvar capacitor bank, high voltage capacitor cabinet, vacuum contactor capacitor switching, detuned series reactor, power factor correction 10kv, advanced capacitor cabinet, capacitor cabinet for end users, capacitor cabinet for retailers, capacitor cabinet specifications, fireproof capacitor cabinet, shockproof capacitor cabinet